BTU Calculator

Estimate the air conditioning or heating capacity a room needs in BTU per hour, kilowatts and tons, from its size, sun, occupants and climate.

BTU calculator
I need
Room measured in
Capacity needed

    Cooling sizes follow the ENERGY STAR room air conditioner guide for rooms with 8 ft ceilings, scaled for taller ceilings. Heating uses common rule-of-thumb loads per square foot. For whole-house systems, ask a heating and cooling professional for a full load calculation (such as ACCA Manual J).

    On this page

    The BTU calculator estimates the cooling or heating capacity a room needs, in British thermal units per hour (BTU/h), from its size and a few details about how it’s used. A 15 ft by 20 ft room (300 sq ft) with an 8 ft ceiling needs an air conditioner of about 8,000 BTU/h under the ENERGY STAR sizing guide. A sunny 20 by 20 ft room used by four people needs about 12,200 BTU/h, so a 14,000 BTU unit is the nearest standard size that’s large enough.

    Choosing the right size matters. An undersized air conditioner or heater runs constantly and still can’t keep the room comfortable. An oversized air conditioner cools the room quickly but switches off before it has removed enough moisture, leaving the air cool but clammy, and it wastes energy by cycling on and off.

    How to use the BTU calculator

    1. Choose air conditioning or heating.
    2. Choose feet or metres and enter the room’s length, width and ceiling height. For an L-shaped room, add the areas of the two parts and enter the total as the length with a width of 1.
    3. For cooling, choose how sunny the room is, enter the number of people who usually use it, and choose Kitchen if it’s a kitchen or a room open to one.
    4. For heating, choose your climate and the standard of the room’s insulation.
    5. Select Calculate BTU. You’ll see the capacity needed in BTU per hour, kilowatts and tons, and a breakdown of each adjustment.

    How cooling capacity is calculated

    The cooling estimate follows the room air conditioner sizing guide published by the US ENERGY STAR programme. It starts with a base capacity for the floor area, assuming an 8 ft ceiling:

    Room areaCapacityRoom areaCapacity
    100 to 150 sq ft5,000 BTU/h450 to 550 sq ft12,000 BTU/h
    150 to 250 sq ft6,000 BTU/h550 to 700 sq ft14,000 BTU/h
    250 to 300 sq ft7,000 BTU/h700 to 1,000 sq ft18,000 BTU/h
    300 to 350 sq ft8,000 BTU/h1,000 to 1,200 sq ft21,000 BTU/h
    350 to 400 sq ft9,000 BTU/h1,200 to 1,400 sq ft23,000 BTU/h
    400 to 450 sq ft10,000 BTU/h1,400 to 1,500 sq ft24,000 BTU/h
    1,500 to 2,000 sq ft30,000 BTU/h
    2,000 to 2,500 sq ft34,000 BTU/h

    The calculator then applies the standard adjustments from the same guide:

    • Heavily shaded room: reduce the capacity by 10%.
    • Very sunny room: increase it by 10%.
    • More than two regular occupants: add 600 BTU/h for each extra person.
    • Kitchen: add 4,000 BTU/h for the heat from cooking appliances.

    Because the table assumes an 8 ft ceiling, the calculator scales the result in proportion for taller ceilings. A room with a 10 ft ceiling has 25% more air to cool than the same room with an 8 ft ceiling.

    Worked example

    A 20 × 20 ft room is 400 sq ft, which falls in the 400 to 450 sq ft band: 10,000 BTU/h. It’s very sunny, so add 10% to get 11,000 BTU/h. Four people use it, two more than the baseline, adding 2 × 600 = 1,200 BTU/h. The total is 12,200 BTU/h. Standard units come in sizes such as 12,000 and 14,000 BTU, so a 14,000 BTU unit is the safe choice, or a 12,000 BTU unit if the room is rarely at full occupancy on the hottest days.

    How heating capacity is estimated

    Heating needs depend heavily on how cold your winters are and how well the room keeps heat in. The calculator uses widely used rule-of-thumb heating loads per square foot for five climate bands, from about 30 to 35 BTU per sq ft in hot climates to 50 to 60 BTU per sq ft in very cold ones. It then adjusts for the ceiling height and for insulation: well-insulated modern rooms with double glazing need about 15% less, and older, poorly insulated rooms with single glazing need about 25% more.

    For example, a 300 sq ft room in a mild climate with average insulation needs roughly 300 × 40 to 300 × 45, or 12,000 to 13,500 BTU/h, which is about 3.5 to 4 kW. The same room in a cold climate with poor insulation needs about 16,900 to 18,750 BTU/h.

    These figures are a starting point for choosing a space heater, radiator or heat pump for a single room. Whole-house heating systems should be sized with a proper heat loss calculation.

    BTU, kilowatts and tons

    • 1 BTU is the energy needed to raise the temperature of one pound of water by one degree Fahrenheit. Air conditioner and heater capacities are given in BTU per hour, often shortened to just BTU.
    • 1 kilowatt equals about 3,412 BTU/h. Heat pumps and heaters outside the US are usually rated in kW, so a 3.5 kW unit is about 12,000 BTU/h.
    • 1 ton of cooling equals 12,000 BTU/h, the rate of cooling from melting one short ton of ice in 24 hours. Central air conditioners are often sized in tons, such as a 2.5-ton system (30,000 BTU/h).

    Estimating running costs

    Once you know the size, you can estimate what an air conditioner will cost to run. Divide the BTU rating by the unit’s efficiency rating (EER or CEER) to get its approximate power draw in watts. An 8,000 BTU unit with a CEER of 10.9 draws about 8,000 ÷ 10.9 = 734 watts at full output. Running it for 8 hours a day uses about 5.9 kWh. At an electricity price of $0.17 per kWh, that’s roughly $1.00 a day, or about $30 a month. A more efficient model with a CEER of 12 would cost about $27 a month for the same cooling. Real costs are usually lower, because the unit cycles down once the room reaches the set temperature, but the calculation is a useful way to compare models.

    Other factors that affect the size you need

    • Windows: large, south- or west-facing windows let in a lot of heat in summer and lose heat in winter.
    • Climate and humidity: very hot or humid areas may need a little more cooling capacity than the base table suggests.
    • Location in the building: top-floor rooms under a roof and rooms with several outside walls gain and lose more heat than interior rooms.
    • Appliances and electronics: computers, gaming equipment and other devices add heat. A home office full of equipment may need a little extra cooling.
    • Open-plan spaces: if a room is open to a hallway or another room, include the connected area, because the air will mix.

    Tips for choosing an air conditioner or heater

    • Don’t oversize. For air conditioners, choose the nearest size at or slightly above the calculated figure rather than going much bigger.
    • Look at efficiency ratings. A higher EER or CEER for room air conditioners, or a higher SEER2 for central systems, means lower running costs for the same cooling.
    • Consider inverter models. Inverter air conditioners and heat pumps adjust their output instead of switching fully on and off, which handles a range of room sizes and conditions more efficiently.
    • Improve the room first. Closing curtains on sunny windows, sealing draughts and adding insulation can reduce the capacity you need and the cost of running it.
    • Check the electrical supply. Larger units may need a dedicated circuit or a 240 V outlet.

    Related calculations

    You may also find the electricity calculator useful to work out the running cost of an appliance, while the square footage calculator lets you find the area of rooms and plots.

    Frequently asked questions

    As a starting point, about 20 BTU per square foot for cooling. A 300 sq ft room needs about 8,000 BTU under the ENERGY STAR guide, adjusted for sun, people and ceiling height.

    A 144 sq ft bedroom or living room needs about 5,000 BTU of cooling. As a kitchen, it needs about 9,000 BTU.

    About 450 to 550 square feet under normal conditions with an 8 ft ceiling.

    No. An oversized unit cools too quickly and switches off before removing enough humidity, leaving the room damp and uncomfortable.

    Divide BTU per hour by about 3,412. For example, 12,000 BTU/h is about 3.5 kW.

    Add 10% for a very sunny room and reduce by 10% for a heavily shaded one.

    Yes. Sizing tables assume an 8 ft ceiling. A 10 ft ceiling means about 25% more air to cool or heat.

    Roughly 30 to 60 BTU per square foot, depending on your climate and insulation. A 300 sq ft room in a mild climate needs about 12,000 to 13,500 BTU/h.

    It's designed for single rooms and open areas up to 2,500 sq ft. Whole-house systems should be sized with a professional load calculation such as Manual J.