Dew Point Calculator

Calculate the dew point from air temperature and relative humidity, or the relative humidity from the dew point, with a comfort rating and frost warning.

Dew point calculator
Calculate
Temperature unit
Dew point

    Uses the Magnus formula with the Alduchov–Eskridge constants (a = 17.625, b = 243.04 °C), accurate to within about 0.4 °C for temperatures from −40 °C to 50 °C. Comfort levels are general guides for how humid air feels.

    On this page

    The dew point calculator finds the temperature at which air becomes saturated and moisture starts to condense, from the air temperature and relative humidity, or works out the relative humidity from the temperature and dew point. At 25 °C (77 °F) and 60% humidity, the dew point is 16.7 °C (62.1 °F), which feels humid and a little sticky. If the air cooled by 8.3 °C, dew would start to form. The calculator also describes how comfortable the air feels and warns when frost is likely.

    It’s useful for weather watchers, gardeners worried about frost, people dealing with condensation and damp at home, painters and builders who must avoid condensation on surfaces, and anyone who wants a better measure of mugginess than relative humidity alone.

    How to use the dew point calculator

    1. Choose what to calculate: the dew point, or the relative humidity.
    2. Choose °C or °F.
    3. Enter the air temperature and either the relative humidity or the dew point.
    4. Select Calculate. You’ll see the result in both units, the dew point spread, a comfort rating and, when relevant, a frost warning.

    What is the dew point?

    Air contains water vapour, and warm air can hold more than cold air. If air is cooled without adding or removing moisture, it eventually reaches a temperature at which it can’t hold all its water vapour. That temperature is the dew point. Cool the air any further, and the excess vapour condenses into dew, fog, cloud or condensation on cold surfaces. When the dew point is below freezing, the moisture forms frost instead.

    Unlike relative humidity, which changes as the temperature rises and falls during the day, the dew point stays fairly steady unless moisture is added or removed. That makes it a more reliable measure of how much moisture is actually in the air.

    The formula

    The calculator uses the Magnus formula, a widely used approximation, with constants published by Alduchov and Eskridge (a = 17.625 and b = 243.04 °C):

    γ = ln(RH ÷ 100) + a × T ÷ (b + T)

    Dew point = b × γ ÷ (a − γ)

    Here T is the air temperature in °C and RH is the relative humidity in percent. To find relative humidity from the dew point (Td), the formula is reversed: RH = 100 × exp(a × Td ÷ (b + Td) − a × T ÷ (b + T)). The approximation is accurate to within about 0.4 °C between −40 °C and 50 °C, which is more than enough for everyday use.

    Worked examples

    • 25 °C, 60%: γ = ln(0.6) + 17.625 × 25 ÷ 268.04 = −0.511 + 1.644 = 1.133, so the dew point is 243.04 × 1.133 ÷ (17.625 − 1.133) = 16.7 °C.
    • 30 °C, 80%: dew point 26.2 °C (79 °F), which feels extremely oppressive.
    • −5 °C, 70%: dew point −9.6 °C, so frost can form on surfaces that cool below that temperature.
    • Relative humidity: at 20 °C with a dew point of 10 °C, the relative humidity is 52.5%.

    Dew point and comfort

    For judging how humid it feels, the dew point is more useful than relative humidity. Many forecasters use a scale like this:

    Dew pointHow it feels
    Below 10 °C (50 °F)Dry and very comfortable
    10–13 °C (50–55 °F)Comfortable
    13–16 °C (55–60 °F)Pleasant, slightly humid
    16–18 °C (60–65 °F)Humid and somewhat sticky
    18–21 °C (65–70 °F)Very humid and uncomfortable
    21–24 °C (70–75 °F)Oppressive
    Above 24 °C (75 °F)Extremely oppressive

    That’s why a 30 °C day in a desert can feel more comfortable than a 27 °C day by the sea: the desert air has a much lower dew point, even if the temperature is higher.

    Practical uses

    • Frost forecasting: on clear, calm nights, the temperature often falls towards the dew point. A dew point below 0 °C signals a risk of frost for gardeners and growers.
    • Fog: when the temperature and dew point are within a degree or two of each other, fog or low cloud is likely.
    • Condensation at home: water forms on windows, walls and pipes whose surface temperature is below the indoor dew point. Lowering indoor humidity, improving ventilation and insulating cold surfaces reduce condensation and mould.
    • Painting and coatings: many paint and coating manufacturers specify that the surface must be at least 3 °C (5 °F) above the dew point during application, so moisture doesn’t form under the coating.
    • Weather and storms: high dew points provide moisture for thunderstorms and make heat more dangerous by reducing the body’s ability to cool.

    How dew forms

    On clear, calm nights, the ground and objects near it lose heat by radiation to the open sky and cool faster than the air above. When a blade of grass, a car roof or a spider’s web cools below the dew point, water vapour condenses on it as droplets. Cloudy or windy nights produce less dew because clouds trap heat and wind mixes warmer air down to the surface. That’s why the heaviest dew and frost often follow still, starlit nights.

    Dew points in different climates

    Dew points vary enormously around the world. In deserts and cold, dry continental winters, dew points can fall well below 0 °C, even on warm afternoons. In tropical coastal regions and during humid summers in places such as the south-eastern United States, South and South-East Asia and the Gulf coasts, dew points of 24 °C (75 °F) or more are common, making the air feel heavy even when the temperature isn’t extreme. Mountain climates usually have lower dew points because cooler air holds less moisture.

    Measuring humidity

    Home weather stations and digital hygrometers measure relative humidity with electronic sensors, usually accurate to within a few percent. A traditional psychrometer uses two thermometers, one with its bulb kept wet; evaporation cools the wet bulb, and the difference between the two readings gives the humidity. Weather services use calibrated instruments in ventilated shelters away from buildings. Place a home sensor away from heat sources, direct sun and kitchens or bathrooms for representative readings.

    Dew point spread

    The difference between the air temperature and the dew point is called the dew point spread or depression. A large spread means dry air; a small one means air close to saturation. Pilots use it to anticipate fog and low cloud, and a rough rule of thumb is that the base of cumulus clouds forms about 125 metres higher for every degree Celsius of spread at ground level (about 400 feet per °F). The calculator shows the spread with every dew point result.

    Indoor humidity

    Indoor relative humidity of roughly 40 to 60% is generally recommended for comfort and to limit mould and dust mites. In winter, when outdoor air is cold, keeping humidity lower helps prevent condensation on windows. Use the relative humidity mode to check: if your indoor temperature is 20 °C and you want to keep the dew point below the temperature of a cold window at 8 °C, the relative humidity needs to stay below about 46%, because air at 20 °C and 46% humidity has a dew point of about 8 °C.

    Related calculations

    For related questions, use the heat index calculator to find the heat index from temperature and humidity, or the wind chill calculator to find the wind chill from air temperature and wind speed.

    Frequently asked questions

    The temperature to which air must cool to become saturated, so that water vapour starts to condense as dew, fog or condensation.

    Use the Magnus formula with the air temperature and relative humidity. At 25 °C and 60% humidity, the dew point is about 16.7 °C.

    Below about 13 °C (55 °F) feels comfortable. Above 18 °C (65 °F) feels humid, and above 21 °C (70 °F) feels oppressive.

    Relative humidity is the percentage of moisture the air holds compared with its maximum at that temperature, so it changes as temperature changes. The dew point measures the actual moisture content.

    No. At most it equals the temperature, when the air is saturated at 100% relative humidity.

    Moisture forms frost rather than dew on surfaces that cool below the dew point.

    The glass is colder than the dew point of the indoor air, so water vapour condenses on it. Ventilation and lower indoor humidity help.

    Choose Relative humidity, enter the air temperature and dew point, and the calculator applies the reversed Magnus formula. 20 °C with a 10 °C dew point is about 52.5%.

    The difference between the air temperature and the dew point. A small spread means air close to saturation and a higher chance of fog.

    The Magnus formula with these constants is accurate to within about 0.4 °C between −40 °C and 50 °C.

    Without cloud cover, the ground loses heat quickly to the sky and cools below the dew point, so moisture condenses on grass and other surfaces.

    Roughly 40 to 60% relative humidity is generally recommended for comfort and to limit mould, with lower levels in cold weather to avoid window condensation.